The universal clearance groove measuring indicator easy cut-in measuring!

With this patent-registered measuring system you can measure easy, exact and fast on your precision turning and groove workpiece the clearance groove and web width as well as whose inside and outside layer and width.

Your benefit

  • all-purpose measurement
  • measuring in seconds
  • direct at the machining center
  • high precision of measurements
  • nondestructive measuring
  • simple application

working range

  • measuring way: 8mm
  • external diameter AD: 10,00-100mm
  • inner diameter ID: 12,00-80mm
  • groove width: 1,10-80mm

Downloads

Product Flyer UniMessFix
Manual UniMessFix

Operating lnstruction of the UniMessFix

Clearance groove measuring outside

Fix the workpiece in position

Keep the position of the measuring key button. In this position neutralize the dial indicator (push it briefly)

Move the workpiece it the measuring key button, at the same time put the measuring key button in the right position by using the deflection lever so that it engages in the clearance groove, move the measuring key button down, read the dial indicator value = a. layer of the clearance groove.

Clearance groove measuring inside. Put the final dimension on the measuring key button

Fix the workpiece in this position on the measuring table, move the measuring key button slowly upwards. Read the dial indicator. Value = b. width of the clearance groove

Clearence groove measuring inside

Put the final dimension on the measuring key button

The final dimension is in position

Put the workpiece over the measuring key button

Push the deflection lever down till it is blocked so that the measuring key button is placed on the measuring table. In this position neutralize the dial indicator (push it briefly)

Move the workpiece to the measuring key button, at the same time put the measuring key button in the right position by using the deflection lever so that it engages in the clearance groove. Move the measuring key button down. Read the dial indicator value = c. layer of the clearence groove

Clearence groove measuring inside: keep the position of the measuring key button. In this position push preset. In preset the final dimension has to be programmed (13,00mm)

Fix the workpiece in this position on the measuring table. Move the measuring key button slowly upwards, read the dial indicator value = d. width of the clearance groove